Study sheet

Electrolytes, Acid-Base and Blood Gases

Sodium, potassium, chloride and CO2, the anion and osmolal gaps, calcium, magnesium, phosphate and iron studies, the four acid-base disorders with expected compensation, blood gas electrodes, CO-oximetry and specimen errors

Checked against current sources November 2026

Page 1 of the Electrolytes, Acid-Base and Blood Gases PDF, a printed page in columns with sections on Ranges the exam uses, Calculations, Acid-base in four steps, Metabolic acidosis by anion gap, Specimen errors that change the answer and Iron studiesEnlarge

Printable PDFLetter landscape, ready to print or keep with your notes

View PDFDownload

Electrolytes, Acid-Base and Blood Gases: PDF preview

Page 1 of the Electrolytes, Acid-Base and Blood Gases PDF, a printed page in columns with sections on Ranges the exam uses, Calculations, Acid-base in four steps, Metabolic acidosis by anion gap, Specimen errors that change the answer and Iron studies

View PDFDownload

Ranges the exam uses

ASCP BOC composite ranges (content guideline, June 9, 2026), for exam use only. ASCP lists no range for calcium, magnesium, phosphate, iron or the gaps: the exam supplies one when it needs it.
AnalyteConventionalSI
Sodium136–145 mmol/L136–145 mmol/L
Potassium3.5–5.1 mmol/L3.5–5.1 mmol/L
Chloride98–107 mmol/L98–107 mmol/L
Total CO₂22–33 mmol/L22–33 mmol/L
Arterial pH7.35–7.457.35–7.45
pCO₂35–44 mm Hg4.7–5.9 kPa
pO₂> 80 mm Hg> 10.6 kPa
O₂ saturation> 95%> 95%
HCO₃⁻ (blood gas)23–29 mmol/L23–29 mmol/L

Calculations

CalculationFormulaReading it
Anion gapNa − (Cl + HCO₃)Normal about 12 mmol/L (Merck); laboratory intervals run from 3–11 to 10–18. With K, (Na + K) − (Cl + HCO₃) runs about 4 mmol/L higher, so its interval is higher too; most clinicians leave K out
Albumin-corrected gapGap + 2.5 × (4.0 − albumin g/dL)Each 1 g/dL fall in albumin hides about 2.5 mmol/L of gap
Calculated osmolality2 × Na + glucose/18 + BUN/2.8 (+ ethanol/4.6)Measured serum osmolality normal 275–295 mOsm/kg (MedlinePlus). Ethanol divisor 4.6 as in the Osmolar Gap calculator; 3.8 and 5 are also published
Osmolal gapMeasured − calculated> 10 mOsm/kg: an unmeasured osmole (toxic alcohol, mannitol)
Corrected calciumTotal Ca + 0.8 × (4.0 − albumin g/dL)Estimate only; ionized calcium settles the question
Transferrin saturationIron ÷ TIBC × 100; TIBC = iron + UIBCIron ÷ UIBC is the classic wrong answer
Henderson-HasselbalchpH = 6.1 + log[HCO₃ ÷ (0.03 × pCO₂)]How the blood gas analyzer calculates HCO₃

Acid-base in four steps

  1. pH: below 7.35 acidemia, above 7.45 alkalemia.
  2. Primary process: the value that moved in the direction of the pH. Low pH with high pCO₂ is respiratory acidosis; low pH with low HCO₃ is metabolic acidosis.
  3. Compensation: compare the other value with the expected one (table below). Off by more than about 10%, or outside Winter's ± 2: a second primary disorder.
  4. In a metabolic acidosis, calculate the anion gap (corrected for albumin), then the delta ratio.
Primary disorderExpected compensation (from pCO₂ 40, HCO₃ 24)
Metabolic acidosisWinter's: pCO₂ = 1.5 × HCO₃ + 8 (± 2)
Metabolic alkalosispCO₂ rises 0.6–0.75 per 1 mmol/L HCO₃ rise, rarely above 55
Acute respiratory acidosisHCO₃ rises 1–2 per 10 mm Hg pCO₂ rise
Chronic respiratory acidosisHCO₃ rises 3–4 per 10 mm Hg
Acute respiratory alkalosisHCO₃ falls 1–2 per 10 mm Hg pCO₂ fall (rarely below 18)
Chronic respiratory alkalosisHCO₃ falls 4–5 per 10 mm Hg (rarely below 14)

Metabolic acidosis by anion gap

High gapNormal gap (hyperchloremic)Low gap
Lactic acidosisDiarrhea, ileostomy, fistulasLow albumin (uncorrected gap)
Ketoacidosis: diabetic, alcoholic, starvationRenal tubular acidosis types 1, 2, 4IgG paraprotein (myeloma)
Kidney failure, rhabdomyolysisAcetazolamide, ureterosigmoidostomyLithium, high calcium or magnesium
Methanol, ethylene glycol (osmolal gap too)Rapid saline infusionBromide or iodide read as chloride
Salicylate; 5-oxoproline (chronic acetaminophen)HypoaldosteronismPolymyxin B

Specimen errors that change the answer

ErrorEffectAction
Air bubble in a gas syringepO₂ toward room air (about 150 mm Hg); pCO₂ falls, pH rises, ionized Ca fallsExpel bubbles at once; suppress pO₂, sO₂, pCO₂, iCa
Delay at room temperaturepO₂ falls, pCO₂ rises, pH falls, lactate rises; faster with high WBC or plateletsPlastic syringe: analyze within 15 min for pO₂, 30 min otherwise; do not ice plastic
Excess liquid heparinDilutes pCO₂ and HCO₃; shifts pO₂ toward airDry balanced heparin syringes, filled to volume
HemolysisK, LD, AST and iron riseRecollect; do not report K
Thrombocytosis, extreme leukocytosisSerum K high from cells during clottingHeparin plasma K
Fist clenching, tight tourniquetK up to 1.4 mmol/L higherRecollect without pumping
K₂EDTA contaminationK very high with Ca and Mg very low (ALP low)Suspect, recollect or measure EDTA
Cold storage before separationK leaks from red cellsSeparate promptly
Lipemia or high protein, indirect ISEFalsely low Na (pseudohyponatremia), normal osmolalityDirect ISE (blood gas analyzer)

Iron studies

Normal (Merck): iron 60–150 mcg/dL (11–27 µmol/L) by sex, TIBC 250–450 mcg/dL (45–81 µmol/L), saturation 20–50%, ferritin 30–300 ng/mL. Draw fasting in the morning; iron is highest then.
PatternIronTIBCSaturationFerritin
Iron deficiencyLowHigh< 10–15%< 30 ng/mL (< 100 with inflammation)
Anemia of inflammationLow or normalLow or normalLow or normal> 100 ng/mL
HemochromatosisHighLowHighHigh

In depth

The summary above is what the PDF prints. These sections go further.

Sodium, osmolality and pseudohyponatremia

Hyponatremia is a sodium below 136 mmol/L and hypernatremia a sodium above 145 mmol/L (Merck), matching the ASCP range. Sodium is the main determinant of serum osmolality, so most true hyponatremia is hypo-osmolar (water excess, as in SIADH) and most hypernatremia is water loss (diarrhea, sweating, osmotic diuresis, diabetes insipidus).

TypeMeasured osmolalityMechanismLab clue
True (hypotonic)Low (< 275)Water excess relative to sodiumDirect and indirect ISE agree
PseudohyponatremiaNormalLipid or protein occupies plasma volume; indirect ISE assumes 93% waterDirect ISE sodium normal; lipemic sample or very high protein
Translocational (hyperglycemia, mannitol)HighGlucose draws water out of cellsSodium falls about 1.6 mmol/L per 100 mg/dL glucose rise

Indirect ISE (high-throughput chemistry analyzers) dilutes a fixed sample volume and back-calculates using an assumed plasma water fraction of about 93% (7% solids). When lipid or protein raises the solid fraction, the plasma water fraction falls and the indirect result is falsely low; the sodium in the plasma water is unchanged. Direct ISE (blood gas analyzers, most point-of-care analyzers) measures undiluted sample, reads activity in plasma water and is not affected. In a spiking study, protein was the cause: albumin enrichment produced a mean indirect-minus-direct sodium bias of about −5.7 mmol/L, lipid alone gave no significant bias, and lipid acted mainly as an amplifier of the protein effect (Chopra 2026).

Osmolality is measured by freezing point depression in most laboratories. Vapor pressure osmometers cannot be used for alcohol-containing samples (Lin 2018), so they will not reveal an osmolal gap from ethanol or a toxic alcohol. An osmolal gap above 10 mOsm/kg means an osmotically active substance is present; with a high anion gap acidosis, methanol and ethylene glycol are the concern (Merck). Glucose itself widens the gap at very high concentrations: with glucose above 450 mg/dL the mean osmolal gap by freezing point was 19 mOsm/kg (Lin 2018), and a gap can also come from a transcription error, so check the numbers before calling a toxic alcohol (Tan 2026).

Potassium

Most potassium is inside cells, so anything that releases cell contents into the specimen raises it. Hyperkalemia (Merck: above 5.5 mmol/L; ASCP's upper limit is 5.1) causes peaked T waves, and above 6.5 mmol/L slower conduction, QRS widening and arrhythmias. True causes include kidney failure, adrenal insufficiency, potassium-retaining drugs, cell breakdown (rhabdomyolysis, tumor lysis, burns), insulin deficiency and acidosis. Hypokalemia (below 3.5 mmol/L) comes from gastrointestinal loss, shifts into cells (insulin, beta-2 agonists, thyrotoxicosis) and renal loss (diuretics, aldosterone excess, magnesium deficiency); hypokalemia and hypomagnesemia travel together, and both deficits must be corrected to stop ongoing renal potassium loss (Merck).

Pseudohyperkalemia is a high result with a normal potassium in the patient. Suspect it when the patient has no reason for hyperkalemia and no ECG changes. Hemolysis is the most common cause and also raises LD, AST and iron. Platelets release potassium as a serum tube clots, so a very high platelet count (or extreme leukocytosis) raises serum but not heparin plasma potassium. Repeated fist clenching under a tourniquet can add up to 1.4 mmol/L. Cold storage of unseparated blood lets potassium leak from red cells; familial pseudohyperkalemia (ABCB6, SLC4A1 variants) exaggerates that leak at low temperature (Fujimaru 2025). Pneumatic tube acceleration can hemolyze specimens. Point-of-care and blood gas analyzers use direct ISE on whole blood; in one comparison with indirect ISE serum potassium, the blood gas potassium ran a mean 0.43 mmol/L below the laboratory value (Chothia 2020).

K₂EDTA is a potassium salt and a chelator. In an experiment adding EDTA blood to lithium heparin blood, potassium rose and calcium and magnesium fell significantly from 5% contamination; chloride, iron and LD also fell, and at 43% contamination potassium reached 11.7 mmol/L with calcium at zero (Lima-Oliveira 2014). Fujimaru adds low zinc and ALP. Draw serum and heparin tubes before EDTA tubes. Mild contamination can be confirmed only by measuring EDTA, so the usual answer is a new specimen.

Chloride, total CO₂ and bicarbonate

Total CO₂ on a chemistry panel is mostly bicarbonate plus dissolved CO₂ (0.03 × pCO₂, about 1.2 mmol/L at a pCO₂ of 40), which is one reason its range (22–33 mmol/L) differs from the blood gas HCO₃ range (23–29). The blood gas analyzer does not measure HCO₃: it calculates it from the measured pH and pCO₂ with the Henderson-Hasselbalch equation. When the two disagree, the measured chemistry value is considered more accurate (Merck); the calculated value should fall within about 2 mmol/L of the serum value, and a larger difference is a reason to suspect the specimen (Tucker 2025).

Chloride usually moves opposite to bicarbonate. A high chloride with a low bicarbonate and a normal gap is a hyperchloremic (normal gap) acidosis. Bromide and iodide read as chloride on many methods, falsely raising chloride and producing a low or negative anion gap. The urine anion gap, Na + K − Cl in urine, helps separate gastrointestinal from renal bicarbonate loss in a normal-gap acidosis.

The anion gap in detail

The gap is the unmeasured anions (mainly albumin, plus phosphate, sulfate and organic acids) minus the unmeasured cations. Reference intervals fell when ion-selective electrodes replaced flame photometry: 1970s intervals were 8–16 and 9–17 mmol/L; ISE laboratories have reported 3–11 and 5–12 mmol/L, although many laboratories still list an upper limit of 15–16 mmol/L (Chionh 2026). Each laboratory's interval depends on its calibration, so use the interval a question gives; without one, use 12.

Albumin is the largest unmeasured anion. Hypoalbuminemia lowers the gap and can hide a lactic or ketoacidosis, so correct it: add 2.5 mmol/L for each 1 g/dL that albumin is below 4.0 g/dL (in g/L: gap + 0.25 × (40 − albumin)). Spurious high gaps come from severe hyperphosphatemia, severe hypertriglyceridemia, hyperalbuminemia and IgA paraprotein; true low gaps from cationic IgG paraproteins, hypercalcemia, hypermagnesemia, lithium and polymyxin B (Fong 2026).

Delta gap (Merck): the patient's gap minus the normal gap. Add it to the measured HCO₃; if the sum is above the normal HCO₃, a metabolic alkalosis is also present. The delta ratio (Tucker) says the same as a ratio: (gap − 12) ÷ (24 − HCO₃). Below 0.8, a normal-gap acidosis is added; 0.8–1.2, a pure high-gap acidosis; above 1.2, a metabolic alkalosis is added.

Acid-base physiology and the compensation rules

pH = −log[H⁺]; at pH 7.40, H⁺ is 40 nmol/L (normal 37–43 nmol/L, pH 7.43–7.37). The bicarbonate-CO₂ system is the main extracellular buffer; phosphates and proteins, including hemoglobin, buffer inside cells, and bone buffers prolonged acid loads. The lungs adjust CO₂ within minutes to hours, about 50–75% effectively; the kidneys reabsorb or excrete HCO₃ over hours to days (Merck). That difference is why respiratory disorders have an acute and a chronic compensation value.

DisorderMerckTucker 2025
Metabolic acidosispCO₂ = 1.5 × HCO₃ + 8 ± 2; about 1.2 mm Hg per 1 mmol/L fallpCO₂ falls 1.25 × HCO₃ fall
Metabolic alkalosis0.6–0.75 mm Hg per 1 mmol/L rise; not above about 550.6 × HCO₃ rise
Acute respiratory acidosisHCO₃ +1–2 per 10 mm Hg0.1 × pCO₂ rise
Chronic respiratory acidosisHCO₃ +3–4 per 10 mm Hg0.4 × pCO₂ rise
Acute respiratory alkalosisHCO₃ −1–2 per 10 mm Hg0.2 × pCO₂ fall, not below 18
Chronic respiratory alkalosisHCO₃ −4–5 per 10 mm Hg0.4 × pCO₂ fall, not below 14
DisorderCommon causes
Respiratory acidosisCOPD or asthma exacerbation, pneumonia, pulmonary edema; neuromuscular weakness (Guillain-Barré, myasthenia, severe hypokalemia or hypophosphatemia); opioids and sedatives, stroke
Respiratory alkalosisAnxiety, pain, hypoxemia (high altitude, pneumonia, pulmonary embolism), progesterone, sepsis, fever, cirrhosis, salicylate overdose (Tucker 2025)
Metabolic acidosisSee the anion gap table on the one-page part
Metabolic alkalosisMost often loss of gastric acid and chloride (vomiting, nasogastric suction) and diuretics; also primary and secondary hyperaldosteronism, Bartter and Gitelman syndromes, licorice (glycyrrhizin), bicarbonate loading and milk-alkali syndrome, posthypercapnia (Merck). Urine chloride < 20 mmol/L: chloride-responsive (vomiting, past diuretics); > 20 mmol/L without current diuretics: chloride-unresponsive (mineralocorticoid excess)

Venous gases are common outside the ICU. In stable patients venous and arterial pH and pCO₂ differ only slightly, but in circulatory or severe respiratory failure the differences grow, and venous pO₂ says nothing about the lungs (Tucker 2025).

The blood gas analyzer and CO-oximetry

MeasurementSensorPrinciple
pHGlass electrode against a reference electrodePotentiometric: the potential at the H⁺-sensitive glass tip varies with H⁺ activity
pCO₂Severinghaus electrodePotentiometric: a pH electrode behind a Teflon or silicone CO₂-permeable membrane; CO₂ diffuses into the bicarbonate electrolyte layer and changes its pH in proportion to pCO₂
pO₂Clark electrodeAmperometric: O₂ crosses a polymer membrane and is reduced at a platinum cathode polarized at about −0.7 V against an Ag/AgCl anode; the current is linear with oxygen
Na, K, Ca²⁺, ClIon-selective electrodesDirect ISE on undiluted whole blood
HCO₃, base excessNoneCalculated
O₂Hb, HHb, COHb, MetHbCO-oximeterSpectrophotometry of lysed blood at four or more wavelengths

A saturation the analyzer calculates from pO₂ assumes all hemoglobin is normal. In carbon monoxide poisoning, the pO₂ and calculated saturation are normal while oxygen content is not, and the pulse oximeter cannot tell carboxyhemoglobin from oxyhemoglobin, so it reads falsely high; carboxyhemoglobin must be measured by CO-oximetry, and a venous sample is acceptable (Merck). Methemoglobin absorbs most at 635 nm and absorbs the pulse oximeter's two wavelengths (660 and 940 nm) equally, so the pulse oximeter drifts toward about 85% while the calculated saturation stays normal. Normal methemoglobin is below 1%. Sulfhemoglobin (peak 614 nm) can be misread as methemoglobin by older CO-oximeters; adding cyanide turns methemoglobin bright red (cyanomethemoglobin) but leaves sulfhemoglobin unchanged (Twine 2026). Methylene blue, some vitamin B12 preparations and fetal hemoglobin can interfere with CO-oximetry (Baird 2013).

Blood gas specimens

Room air has a pO₂ near 150 mm Hg and almost no CO₂. A bubble therefore pulls the specimen's pO₂ toward 150 (up if the patient's pO₂ is lower, down if it is higher on supplemental oxygen) and lets CO₂ escape, so pCO₂ falls and pH rises; the higher pH lowers ionized calcium. With a 20% bubble analyzed about 15 minutes after a venous draw, pO₂ rose 10.8%, sO₂ 11.2%, pCO₂ fell 4.8% and ionized calcium 1.3% (Pighi 2024). Expel bubbles immediately; a syringe that arrives with a bubble should not have its pO₂, sO₂, pCO₂ or ionized calcium reported.

Cells keep metabolizing in the syringe. At room temperature pO₂ falls about 2 mm Hg per hour, pCO₂ rises about 1 mm Hg per hour and pH falls 0.02–0.03 per hour; glucose falls and lactate rises as the sample turns anaerobic. Very high leukocyte or platelet counts make the pO₂ fall much faster. IFCC advice cited by Baird: analyze plastic syringes at room temperature within 15 minutes when pO₂ or saturation is wanted, otherwise within 30 minutes. Do not ice plastic syringes, which become more permeable to gas when cold; icing was a practice for glass syringes.

Use dry, electrolyte-balanced heparin. Liquid heparin dilutes the sample (lowering pCO₂ and HCO₃) and carries dissolved air, and unbalanced heparin binds calcium and other cations. EDTA and oxalate chelate divalent cations and are unsuitable. Mix well after collection and again before analysis to resuspend red cells for hemoglobin and CO-oximetry. Pneumatic tube transport has raised pO₂ and caused hemolysis in some studies.

Calcium

Total serum calcium is 8.8–10.4 mg/dL (2.20–2.60 mmol/L) and ionized calcium 4.7–5.2 mg/dL (1.17–1.30 mmol/L), ranges that vary by laboratory (Merck). About 40% of calcium is bound to protein, mainly albumin, and ionized calcium is about half the total. Low albumin lowers total calcium by about 0.8 mg/dL (0.2 mmol/L) per 1 g/dL, without changing ionized calcium; corrected calcium estimates the effect, but ionized calcium is the preferred test. Acidosis raises ionized calcium by reducing protein binding and alkalosis lowers it, so an ionized calcium specimen is collected anaerobically and analyzed promptly. Convert mg/dL to mmol/L by multiplying by 0.25.

PTH raises calcium within minutes (renal and intestinal calcium absorption, mobilization of calcium and phosphate from bone, conversion of vitamin D to calcitriol); calcitriol raises intestinal absorption; calcitonin lowers calcium, weakly (Merck). Magnesium below about 1.0 mg/dL impairs PTH release and action, so hypocalcemia with hypomagnesemia corrects only after magnesium is replaced. Citrate in large transfusions and EDTA in some contrast agents lower ionized calcium; EDTA contamination of a specimen lowers it in vitro.

Magnesium and phosphate

AnalyteRangeLowHigh
Magnesium1.7–2.2 mg/dL (0.70–0.91 mmol/L), MedlinePlus; Merck calls < 1.8 mg/dL low, < 1.25 severeAlcohol use, diarrhea, PPIs, loop and thiazide diuretics, aminoglycosides, amphotericin, cisplatin, DKAKidney failure, lithium, adrenal insufficiency, milk-alkali syndrome
PhosphateAdults 2.8–4.5 mg/dL (0.90–1.45 mmol/L), children 4.0–7.0, MedlinePlus; Merck calls < 2.5 mg/dL (0.81 mmol/L) low, < 1 severeRefeeding, recovery from DKA, alcohol, respiratory alkalosis, hyperparathyroidism, aluminum antacids, vitamin D deficiencyKidney failure, hypoparathyroidism, vitamin D excess, phosphate laxatives

Serum magnesium can be normal despite low cell and bone stores (Merck). Children's phosphate interval is higher than adults', so an adult interval must not be applied to a child. Phosphate is the classic fall during refeeding of an undernourished patient.

Iron, TIBC, UIBC and saturation

Serum iron is iron carried on transferrin. TIBC is how much iron transferrin could carry, a functional measure of transferrin; UIBC is the unused part, so TIBC = iron + UIBC. Saturation is iron ÷ TIBC × 100. In iron deficiency the liver makes more transferrin, so TIBC rises while iron and saturation fall. In inflammation iron is held in stores, so iron falls, TIBC is normal or low and ferritin, an acute-phase reactant, is normal or high. In iron overload iron and saturation are high and TIBC low; TIBC is also low in liver disease, malnutrition and protein loss, and high in late pregnancy.

Serum iron is highest in the morning and falls through the day, and recent meals or supplements raise it, so iron studies are drawn fasting in the morning with supplements stopped at least 24 hours. Hemolysis raises serum iron (red cells contain it), and EDTA contamination lowers it. Ferritin below 30 ng/mL is specific for iron deficiency; with inflammation, values up to 100 ng/mL can still mean deficiency (Merck).

Practice free in your browser600+ exam-style questions with rationales. Free today, no account, no ads. Pro is coming in January 2027. Also free on Google Play.

Related study sheets

Calculators for this topic

Sources

  1. ASCP Board of Certification. Medical Laboratory Scientist MLS(ASCP) Examination Content Guideline, revised June 9, 2026 (reference ranges and calculations) Link
  2. Merck Manual Professional. Acid-Base Disorders Link
  3. Merck Manual Professional. Acid-Base Regulation Link
  4. Merck Manual Professional. Metabolic Alkalosis Link
  5. Merck Manual Professional. Metabolic Acidosis Link
  6. Merck Manual Professional. Hyponatremia Link
  7. Merck Manual Professional. Hypernatremia Link
  8. Merck Manual Professional. Hyperkalemia Link
  9. Merck Manual Professional. Hypokalemia Link
  10. Merck Manual Professional. Overview of Disorders of Calcium Concentration Link
  11. Merck Manual Professional. Hypocalcemia Link
  12. Merck Manual Professional. Hypomagnesemia Link
  13. Merck Manual Professional. Hypophosphatemia Link
  14. Merck Manual Professional. Iron Deficiency Anemia Link
  15. Merck Manual Professional. Carbon Monoxide Poisoning Link
  16. Tucker AM, Johnson TN. Respiratory acid-base disorders. Nutr Clin Pract. 2025 Link
  17. Fong JMN, Tang GXJ, See KC. The anion gap: basic chemistry, powerful clinical implications. Singapore Med J. 2026 Link
  18. Chionh CY, Tien CS, Yeon W, et al. Diagnostic threshold and performance of anion gap in screening for high anion gap metabolic acidosis. Singapore Med J. 2026 Link
  19. Baird G. Preanalytical considerations in blood gas analysis. Biochem Med (Zagreb). 2013;23(1):19-27 Link
  20. Pighi L, Salvagno GL, Ferraro R, et al. Impact of an air bubble within the syringe on test results obtained with a modern blood gas analyzer. J Med Biochem. 2024 Link
  21. Chopra P, Bharti G, Gupta A, et al. Impact of total protein and triglycerides on the comparability of sodium and potassium measurements by direct and indirect ion-selective electrodes. EJIFCC. 2026 Link
  22. Tan S, Yong A, Saw S, Sethi S. The truth lies within the gap. EJIFCC. 2026 Link
  23. Lima-Oliveira G, Salvagno GL, Danese E, et al. Contamination of lithium heparin blood by K2-EDTA: an experimental evaluation. Biochem Med (Zagreb). 2014 Link
  24. Ercan Ş, Ramadan B, Gerenli O. Order of draw of blood samples affect potassium results without K-EDTA contamination during routine workflow. Biochem Med (Zagreb). 2021 Link
  25. Fujimaru T, Hirose K, Yazawa M, et al. Pathophysiology and causes of hyperkalemia: unraveling causes beyond kidney dysfunction. Clin Exp Nephrol. 2025 Link
  26. Chothia MY, Kassum P, Zemlin A. A method comparison study of a point-of-care blood gas analyser with a laboratory auto-analyser for the determination of potassium. Biochem Med (Zagreb). 2020 Link
  27. Twine AJ, Rees DC. Methaemoglobinaemia: from pathophysiology to contemporary clinical management. Br J Haematol. 2026 Link
  28. Marassi V, Giordani S, Kurevija A, et al. The challenges of O2 detection in biological fluids: classical methods and translation to clinical applications. Int J Mol Sci. 2022 Link
  29. Wang Y, Xu H, Zhang J, Li G. Electrochemical sensors for clinic analysis. Sensors (Basel). 2008 Link
  30. Sanagustín MN, Osredkar J. Blood gas analysis: clinical applications, interpretation and future directions. Med Int (Lond). 2026 Link
  31. Lin KY, Chen PC, Chen SC, et al. Evaluation of the effects of glucose on osmolal gap using freezing point depression and vapor pressure methods. Kaohsiung J Med Sci. 2018 Link
  32. MedlinePlus. Osmolality blood test Link
  33. MedlinePlus. Magnesium blood test Link
  34. MedlinePlus. Phosphorus blood test Link
  35. MedlinePlus. Total iron binding capacity Link
  36. Testing.com (ADLM). Osmolality and Osmolal Gap Link
  37. Testing.com (ADLM). Iron Tests Link
  38. Testing.com (ADLM). Electrolytes Link